fix(brownout): Fixed threshold value for esp32h4 and esp32h21
This commit is contained in:
@@ -14,6 +14,7 @@
|
||||
#include <stdbool.h>
|
||||
#include "esp_bit_defs.h"
|
||||
#include "soc/lp_analog_peri_struct.h"
|
||||
#include "hal/assert.h"
|
||||
#include "hal/regi2c_ctrl.h"
|
||||
#include "hal/psdet_types.h"
|
||||
#include "soc/regi2c_brownout.h"
|
||||
@@ -65,10 +66,13 @@ static inline void brownout_ll_reset_config(bool reset_ena, uint32_t reset_wait,
|
||||
/**
|
||||
* @brief Set brown out threshold voltage
|
||||
*
|
||||
* @param threshold brownout threshold
|
||||
* @note Only level 7 (~2.96V) is valid on ESP32-H21.
|
||||
*
|
||||
* @param threshold dcdc_brno from CONFIG_ESP_BROWNOUT_DET_LVL
|
||||
*/
|
||||
static inline void brownout_ll_set_threshold(uint8_t threshold)
|
||||
{
|
||||
HAL_ASSERT(threshold == 7);
|
||||
REGI2C_WRITE_MASK(I2C_BOD, I2C_BOD_THRESHOLD, threshold);
|
||||
}
|
||||
|
||||
|
||||
@@ -14,6 +14,7 @@
|
||||
#include <stdbool.h>
|
||||
#include "esp_bit_defs.h"
|
||||
#include "soc/lp_analog_peri_struct.h"
|
||||
#include "hal/assert.h"
|
||||
#include "hal/regi2c_ctrl.h"
|
||||
#include "hal/psdet_types.h"
|
||||
#include "soc/regi2c_brownout.h"
|
||||
@@ -65,10 +66,13 @@ static inline void brownout_ll_reset_config(bool reset_ena, uint32_t reset_wait,
|
||||
/**
|
||||
* @brief Set brown out threshold voltage
|
||||
*
|
||||
* @param threshold brownout threshold
|
||||
* @note Only level 7 (~2.96V) is valid on ESP32-H4.
|
||||
*
|
||||
* @param threshold dcdc_brno from CONFIG_ESP_BROWNOUT_DET_LVL
|
||||
*/
|
||||
static inline void brownout_ll_set_threshold(uint8_t threshold)
|
||||
{
|
||||
HAL_ASSERT(threshold == 7);
|
||||
REGI2C_WRITE_MASK(I2C_BOD, I2C_BOD_THRESHOLD, threshold);
|
||||
}
|
||||
|
||||
|
||||
@@ -13,62 +13,18 @@ menu "Power Supplier"
|
||||
choice ESP_BROWNOUT_DET_LVL_SEL
|
||||
prompt "Brownout voltage level"
|
||||
depends on ESP_BROWNOUT_DET
|
||||
default ESP_BROWNOUT_DET_LVL_SEL_4
|
||||
default ESP_BROWNOUT_DET_LVL_SEL_7
|
||||
help
|
||||
The brownout detector will reset the chip when the supply voltage is approximately
|
||||
below this level. Note that there may be some variation of brownout voltage level
|
||||
between each chip.
|
||||
Only level 7 is supported on ESP32-H21 (~2.96V). Other values would also
|
||||
affect PCM/LDO/VDD_DIG and are not offered.
|
||||
|
||||
#The voltage levels here are estimates, more work needs to be done to figure out the exact voltages
|
||||
#of the brownout threshold levels.
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_15
|
||||
bool "3.77V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_14
|
||||
bool "3.68V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_13
|
||||
bool "3.58V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_12
|
||||
bool "3.47V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_11
|
||||
bool "3.37V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_10
|
||||
bool "3.26V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_9
|
||||
bool "3.16V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_8
|
||||
bool "3.06V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_7
|
||||
bool "2.96V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_6
|
||||
bool "2.86V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_5
|
||||
bool "2.75V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_4
|
||||
bool "2.66V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_3
|
||||
bool "2.55V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_2
|
||||
bool "2.45V"
|
||||
|
||||
endchoice
|
||||
|
||||
config ESP_BROWNOUT_DET_LVL
|
||||
int
|
||||
default 2 if ESP_BROWNOUT_DET_LVL_SEL_2
|
||||
default 3 if ESP_BROWNOUT_DET_LVL_SEL_3
|
||||
default 4 if ESP_BROWNOUT_DET_LVL_SEL_4
|
||||
default 5 if ESP_BROWNOUT_DET_LVL_SEL_5
|
||||
default 6 if ESP_BROWNOUT_DET_LVL_SEL_6
|
||||
default 7 if ESP_BROWNOUT_DET_LVL_SEL_7
|
||||
default 8 if ESP_BROWNOUT_DET_LVL_SEL_8
|
||||
default 9 if ESP_BROWNOUT_DET_LVL_SEL_9
|
||||
default 10 if ESP_BROWNOUT_DET_LVL_SEL_10
|
||||
default 11 if ESP_BROWNOUT_DET_LVL_SEL_11
|
||||
default 12 if ESP_BROWNOUT_DET_LVL_SEL_12
|
||||
default 13 if ESP_BROWNOUT_DET_LVL_SEL_13
|
||||
default 14 if ESP_BROWNOUT_DET_LVL_SEL_14
|
||||
default 15 if ESP_BROWNOUT_DET_LVL_SEL_15
|
||||
|
||||
|
||||
config ESP_BROWNOUT_USE_INTR
|
||||
bool
|
||||
|
||||
@@ -13,62 +13,18 @@ menu "Power Supplier"
|
||||
choice ESP_BROWNOUT_DET_LVL_SEL
|
||||
prompt "Brownout voltage level"
|
||||
depends on ESP_BROWNOUT_DET
|
||||
default ESP_BROWNOUT_DET_LVL_SEL_4
|
||||
default ESP_BROWNOUT_DET_LVL_SEL_7
|
||||
help
|
||||
The brownout detector will reset the chip when the supply voltage is approximately
|
||||
below this level. Note that there may be some variation of brownout voltage level
|
||||
between each chip.
|
||||
Only level 7 is supported on ESP32-H4 (~2.96V). Other values would also
|
||||
affect PCM/LDO/VDD_DIG and are not offered.
|
||||
|
||||
#The voltage levels here are estimates, more work needs to be done to figure out the exact voltages
|
||||
#of the brownout threshold levels.
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_15
|
||||
bool "3.77V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_14
|
||||
bool "3.68V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_13
|
||||
bool "3.58V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_12
|
||||
bool "3.47V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_11
|
||||
bool "3.37V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_10
|
||||
bool "3.26V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_9
|
||||
bool "3.16V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_8
|
||||
bool "3.06V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_7
|
||||
bool "2.96V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_6
|
||||
bool "2.86V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_5
|
||||
bool "2.75V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_4
|
||||
bool "2.66V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_3
|
||||
bool "2.55V"
|
||||
config ESP_BROWNOUT_DET_LVL_SEL_2
|
||||
bool "2.45V"
|
||||
|
||||
endchoice
|
||||
|
||||
config ESP_BROWNOUT_DET_LVL
|
||||
int
|
||||
default 2 if ESP_BROWNOUT_DET_LVL_SEL_2
|
||||
default 3 if ESP_BROWNOUT_DET_LVL_SEL_3
|
||||
default 4 if ESP_BROWNOUT_DET_LVL_SEL_4
|
||||
default 5 if ESP_BROWNOUT_DET_LVL_SEL_5
|
||||
default 6 if ESP_BROWNOUT_DET_LVL_SEL_6
|
||||
default 7 if ESP_BROWNOUT_DET_LVL_SEL_7
|
||||
default 8 if ESP_BROWNOUT_DET_LVL_SEL_8
|
||||
default 9 if ESP_BROWNOUT_DET_LVL_SEL_9
|
||||
default 10 if ESP_BROWNOUT_DET_LVL_SEL_10
|
||||
default 11 if ESP_BROWNOUT_DET_LVL_SEL_11
|
||||
default 12 if ESP_BROWNOUT_DET_LVL_SEL_12
|
||||
default 13 if ESP_BROWNOUT_DET_LVL_SEL_13
|
||||
default 14 if ESP_BROWNOUT_DET_LVL_SEL_14
|
||||
default 15 if ESP_BROWNOUT_DET_LVL_SEL_15
|
||||
|
||||
|
||||
config ESP_BROWNOUT_USE_INTR
|
||||
bool
|
||||
|
||||
Reference in New Issue