feat(esp_hw_support): fix pvt charge pump bug on chip761

This commit is contained in:
yanzihan@espressif.com
2026-01-26 11:46:04 +08:00
committed by zlq
parent 569752d2c9
commit 94838b4106
@@ -1,5 +1,5 @@
/*
* SPDX-FileCopyrightText: 2025 Espressif Systems (Shanghai) CO LTD
* SPDX-FileCopyrightText: 2025-2026 Espressif Systems (Shanghai) CO LTD
*
* SPDX-License-Identifier: Apache-2.0
*/
@@ -101,13 +101,11 @@ void pvt_auto_dbias_init(void)
SET_PERI_REG_BITS(PVT_COMB_PD_SITE2_UNIT0_VT2_CONF2_REG, PVT_MONITOR_EDG_MOD_VT2_PD_SITE2_UNIT0, PVT_EDG_MODE, PVT_MONITOR_EDG_MOD_VT2_PD_SITE2_UNIT0_S); // Select edge_mode
SET_PERI_REG_BITS(PVT_COMB_PD_SITE2_UNIT0_VT2_CONF1_REG, PVT_DELAY_LIMIT_VT2_PD_SITE2_UNIT0, PVT_DELAY_NUM_HIGH, PVT_DELAY_LIMIT_VT2_PD_SITE2_UNIT0_S); // The threshold for determining whether the voltage is too high
SET_PERI_REG_BITS(PVT_COMB_PD_SITE2_UNIT1_VT2_CONF1_REG, PVT_DELAY_LIMIT_VT2_PD_SITE2_UNIT1, PVT_DELAY_NUM_LOW, PVT_DELAY_LIMIT_VT2_PD_SITE2_UNIT1_S); // The threshold for determining whether the voltage is too low
SET_PERI_REG_BITS(PVT_COMB_PD_SITE2_UNIT2_VT2_CONF1_REG, PVT_DELAY_LIMIT_VT2_PD_SITE2_UNIT2, PVT_DELAY_NUM_PUMP, PVT_DELAY_LIMIT_VT2_PD_SITE2_UNIT2_S); // The threshold for chargepump
SET_PERI_REG_BITS(PVT_COMB_PD_SITE2_UNIT2_VT1_CONF1_REG, PVT_DELAY_LIMIT_VT1_PD_SITE2_UNIT2, PVT_DELAY_NUM_PUMP, PVT_DELAY_LIMIT_VT1_PD_SITE2_UNIT2_S); // The threshold for chargepump
/*config lp offset for pvt func*/
uint8_t lp_hp_gap = get_lp_hp_gap();
set_pvt_hp_lp_gap(lp_hp_gap);
} else {
ESP_HW_LOGD(TAG, "blk_version is less than 3, pvt auto dbias init not supported in efuse.");
}
}
@@ -135,8 +133,6 @@ void IRAM_ATTR pvt_func_enable(bool enable)
CLEAR_PERI_REG_MASK(PCR_PVT_MONITOR_CONF_REG, PCR_PVT_MONITOR_CLK_EN);
CLEAR_PERI_REG_MASK(PCR_PVT_MONITOR_FUNC_CLK_CONF_REG, PCR_PVT_MONITOR_FUNC_CLK_EN);
}
} else {
ESP_HW_LOGD(TAG, "blk_version is less than 3, pvt enable not supported in efuse.");
}
}
@@ -148,8 +144,6 @@ void charge_pump_init(void)
SET_PERI_REG_BITS(PVT_PMUP_CHANNEL_CFG_REG, PVT_PUMP_CHANNEL_CODE0, PVT_PUMP_CHANNEL_CODE, PVT_PUMP_CHANNEL_CODE0_S); //Set channel code
WRITE_PERI_REG(PVT_PMUP_BITMAP_LOW0_REG, (1 << PVT_PUMP_BITMAP)); // Select monitor cell for charge pump
SET_PERI_REG_BITS(PVT_PMUP_DRV_CFG_REG, PVT_PUMP_DRV0, PVT_PUMP_DRV, PVT_PUMP_DRV0_S); //Configure the charging intensity
} else {
ESP_HW_LOGD(TAG, "blk_version is less than 3, pvt charge_pump init not supported in efuse.");
}
}
@@ -162,8 +156,6 @@ void IRAM_ATTR charge_pump_enable(bool enable)
} else {
CLEAR_PERI_REG_MASK(PVT_PMUP_DRV_CFG_REG, PVT_PUMP_EN); //disable charge pump
}
} else {
ESP_HW_LOGD(TAG, "blk_version is less than 3, pvt charge_pump enable not supported in efuse.");
}
}