change(app_trace): move sysview to component registry

This commit is contained in:
Erhan Kurubas
2025-11-13 10:50:42 +01:00
parent ccc59ed681
commit 7d4ae881c5
66 changed files with 146 additions and 8456 deletions
@@ -134,10 +134,26 @@ New configuration:
CONFIG_APPTRACE_DEST_UART=y
CONFIG_APPTRACE_DEST_UART_NUM=0 # or 1, 2 depending on target
SystemView Configuration
^^^^^^^^^^^^^^^^^^^^^^^^
SEGGER SystemView
^^^^^^^^^^^^^^^^^
The SystemView configuration has been moved to a new location in the menuconfig: ``Component config`` > ``ESP Trace Configuration`` > ``Trace library`` > ``SEGGER SystemView``.
The SystemView component has been moved to a separate repository. `esp_sysview <https://components.espressif.com/components/espressif/esp_sysview>`_ is now a managed component.
Configuration
^^^^^^^^^^^^^^
The SystemView configuration has been moved to a new location in the menuconfig. It becomes visible only when the project adds the ``esp_sysview`` component dependency in ``idf_component.yml`` and the external library is selected in menuconfig.
Add the dependency in your component manifest:
.. code-block:: yaml
dependencies:
espressif/esp_sysview: ^1
Then, in menuconfig, select: ``Component config`` > ``ESP Trace Configuration`` > ``Trace library`` > ``External library from component registry``.
After that, the SystemView configuration can be shown by selecting ``Component config`` > ``SEGGER SystemView Configuration``.